Selecionar página

Válvula de retenção de silenciador de flange H41X-16Q

The H41X-16Q Flange Silencer Check Valve is an automatic backflow prevention valve with a silencing design, offering ≤60dB noise and adjustable slow closing (1-10s) to reduce water hammer by 50%. Suitable for water supply, HVAC, and fire systems, it handles max 16 bar and 0°C-80°C.

Ver mais em Válvula de retenção Catálogo!

Válvula de retenção de silenciador de flange H41X-16Q

ESPECIFICAÇÃO DO MATERIAL
Model H41X-1.0 H41X-1.6
Valve   body(1) Cast iron or   stainless steel Cast steel or   stainless steel
Sealing   ring(2) Nitrile rubber(NBR) Nitrile rubber(NBR)
Spring(3) Stainless steel   wire 1Cr8Ni9Ti Stainless steel   wire 1Cr8Ni9Ti

 

DIMENSIONS(Model 2)
Size Length mm Weight kg
DN50 120 5
DN65 130 6.5
DN80 150 8.2
DN100 160 10.7
DN125 190 15
DN150 210 20
DN200 255 30
DN250 275 58
DN300 310 76
DN350 345 107
DN400 395 149

 

DIMENSIONS(Model 1)
Size Length mm Weight kg
DN50 106 5.5
DN65 126 6.25
DN80 131 6.5
DN100 149 8
DN125 166 11.5
DN150 182 15
DN200 195 23
DN250 242 39
DN300 284 55

DESCRIÇÃO DO PRODUTO

1.The flange silencer check valve is an automatic valve that automatically opens and closes the valve disc by the flow of the medium itself.
2. It is mainly used to prevent the medium from flowing back, to prevent the pump and the drive motor from reversing, and to control the release of the medium in the container.
3.This valve is widely used in water supply and drainage systems, fire protection systems, HVAC systems and water pump outlets to prevent back flow from damaging the pump.

CARACTERÍSTICAS

1.Check reliability Quick response to back flow, high sealing level (leakage rate ≤ 0.1%).
2.Low noise The silencing design makes the closing noise ≤ 60dB, suitable for quiet environments such as hospitals and residential areas.
3.Anti-water hammer The slow closing time is adjustable (1-10 seconds), which effectively reduces water hammer damage (pressure peak is reduced by more than 50%).
4.Low pressure loss Streamlined valve body design, resistance coefficient ≤ 0.5 when fully open.

CANDIDATURA

1.Building water supply and drainage: high-rise building water pump outlet, to prevent water hammer from damaging the pipe when the pump is stopped.
2.HVAC: chilled water circulation system, to reduce the noise of pump start and stop.
3.Fire protection system: protect fire pumps in the sprinkler network to avoid back flow and contamination of water sources.
4.Industrial circulating water: cooling water return pipeline, to reduce the impact of water hammer on the heat exchanger.
5.Municipal water supply: booster pump station outlet, to ensure stable operation of the network.

PRESSÃO DE TRABALHO

Pressão máxima de trabalho 16 bar (230psi).

PADRÃO

O teste do produto é efectuado em conformidade com o teste de pressão da válvula industrial GB/T13927.

GAMA DE TEMPERATURAS

0 °C a 80°C.

REVESTIMENTO

Revestimento epóxi ligado por fusão.