Выбрать страницу

Y43X-16Q Пропорциональный редукционный клапан

The Y43X – 16Q Proportional Pressure Reducing Valve mechanically reduces inlet pressure to outlet pressure at a fixed ratio, ensuring dynamic balance without external control. With a max 16 bar pressure, 0°C – 80°C range, and epoxy coating, it offers proportional constant pressure and maintenance – free design.

View Редукционный клапан Каталог для большего!

Y43X-16Q Пропорциональный редукционный клапан

СПЕЦИФИКАЦИЯ МАТЕРИАЛА
Main technical parameters Water,   Gas
Применяемые носители ≤ 90℃
Применяемая температура ≤ 8℃
Pressure error 0.2MPa
Minimum opening pressure 0.3MPa
Connection   Type Flange,   internal thread
Main parts materials Корпус клапана Tin Bronze Нержавеющая сталь cast   iron
Internals Tin bronze or   stainless steel

 

РАЗМЕРЫ
DN (мм) A1 A D3
25 115 232 115/125
32 124 246 140/150
40 132 256 150/155
50 140 270 165/175
65 155 306 185/200
80 155 320 210/230
100 200 340 240/265
125 220 400 275/300
150 230 429 310/350
200 270 358 355/400

ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ

1.A proportional pressure reducing valve is an automatic valve that reduces the inlet pressure to the outlet pressure at a fixed ratio through mechanical proportional adjustment.
2.Its core function is to stabilize the output pressure, ensure that the downstream pipeline or equipment operates within a safe pressure range
3.Achieve dynamic pressure balance without external control
4.Pressure sensing:Outlet pressure is transmitted to the diaphragm/piston upper chamber through the feedback pipeline.
5.The diaphragm is acted upon by the combined effect of outlet pressure and spring force.
6.Dynamic balance:When outlet pressure increases: the diaphragm moves upward under pressure, pushing the valve disc to move in the closing direction, reducing the medium flow area, and the outlet pressure drops.
7.When outlet pressure decreases: the spring force pushes the diaphragm downward, the valve disc opens to increase the flow area, and the outlet pressure rises.
8.Proportional characteristics: the outlet pressure is always adjusted according to the preset ratio (such as 1/2 of the inlet pressure), regardless of flow changes.
9.Automatic pressure stabilization:The valve disc position is automatically adjusted with the inlet pressure fluctuation to maintain the outlet pressure stable

FEATURE

1.Proportional constant pressure:The outlet pressure is in a fixed ratio with the inlet pressure, which is suitable for scenarios with large inlet pressure fluctuations.
2.Simple structure:No external energy or complex control device, relying on pure mechanical adjustment, high reliability.
3.Maintenance-free design:No electronic components, strong pollution resistance, suitable for media with poor water quality (such as fire water systems).
4.Wide adaptability:Supports liquid and gas media, common ratio range 1.5:1 to 4:1, maximum working pressure up to PN25.

РАБОЧЕЕ ДАВЛЕНИЕ

Максимальное рабочее давление 16 бар (230psi)

СТАНДАРТ

Испытания продукции проводятся в соответствии с GB/T13927 Испытание промышленного клапана давлением

УСТАНОВКА ДАВЛЕНИЯ

Предварительная заводская настройка давления на выходе до 10 бар (144psi)

ДИАПАЗОН ТЕМПЕРАТУР

От 0 °C до 80 °C

ПОКРЫТИЕ

Эпоксидное покрытие с плавкой связью

Y43X-16Q Пропорциональный редукционный клапан Y43X-16Q Пропорциональный редукционный клапан Y43X-16Q Пропорциональный редукционный клапан Y43X-16Q Пропорциональный редукционный клапан

Оставьте свое сообщение