Depósito de espuma fijo Tipo vertical

Dimensiones
Número de modelo Capacidad Galón Estilo Presión de trabajo Ración Brida Caudal
PHYML-200 200 litros 50galones Vertical,Fijo 6-12Bar 3% o 6% 2 1/2'' 4L/S
PHYML-500 500 litros 125 Galones Vertical,Fijo 6-12Bar 3% o 6% 4'' 8-64L/S
PHYML-1000 1000litros 250galones Vertical,Fijo 6-12Bar 3% o 6% 4'' 8-64L/S
PHYML-1500 1500litros 375galones Vertical,Fijo 6-12Bar 3% o 6% 4'' 8-64L/S
PHYML-2000 2000litros 500galones Vertical,Fijo 6-12Bar 3% o 6% 4'' 8-64L/S
PHYML-2500 2500litros 625galones Vertical,Fijo 6-12Bar 3% o 6% 4'' 8-64L/S
PHYML-3000 3000litros 750galones Vertical,Fijo 6-12Bar 3% o 6% 6'' 8-64L/S
PHYML-4000 4000litros 1000galones Vertical,Fijo 6-12Bar 3% o 6% 6'' 8-64L/S
PHYML-5000 5000litros 1250galones Vertical,Fijo 6-12Bar 3% o 6% 8'' 8-64L/S

Especificaciones

1. Operation: Manual
2. Proportioner flange standard: ANSI / BS4504 / GB;
3. Valve body material: carbon steel;
4. Liner material: rubber;
5. Proportioner: standard carbon steel (SS304 stainless steel optional);
6. Ball valve: standard brass (SS304 stainless steel optional);
7. Safety valve: standard brass (SS304 stainless steel optional);
8. Pipeline system: standard carbon steel (SS304 stainless steel optional);

Escenarios de aplicación

1. Foam fire extinguishing system: protect Class B fire high-risk areas such as oil depots, chemical plants, and airport fuel depots.
2. Space-constrained scenarios: vertical design saves floor space (40% less space than horizontal).
3. Anti-cross contamination: The capsule physically isolates the foam liquid from water to avoid premix failure.

Principio de funcionamiento

1. Water injection and pressurization: Fire water is injected into the outer cavity of the capsule → squeezes the foam liquid in the capsule.
2. Quantitative delivery: The foam liquid is squeezed out to the proportion mixer (such as 3%/6% concentration) → mixed with water flow and sprayed.
3. Automatic switching: After the capsule is emptied, the water flow is directly output (the system seamlessly switches to pure water fire extinguishing).

Características

1. Zero residue design: Capsule shrinkage rate > 95%, foam liquid utilization rate is extremely high (residue < 1%).
2. Visual monitoring: liquid level gauge + pressure gauge dual indication (pressure drop alarm when the capsule ruptures).
3. Fast filling: reserve the foam liquid injection port, replenishment does not need to empty the system.

Presión de trabajo

1. Design pressure: 1.0~1.6 MPa (in accordance with NFPA 11 standards), bursting pressure ≥ 3 times the working pressure.
2. Capsule pressure resistance: 0.3~1.2 MPa (low pressure start, high pressure seal anti-leakage).

Depósito de espuma fijo Tipo vertical