ESPECIFICACIÓN DEL MATERIAL
Serial number Code   name Nombre Cantidad Material
1 100X-DN-01 Cuerpo de la válvula 1 QT450-10
2 100X-DN-02 Conjunto del núcleo de la válvula 1 QT450-10+NBR
3 GB/T 5781 Hexagon head   bolts N A2-70
4 GB/T 95 Arandelas planas N A2
5 100X-DN-03 Primavera 1 201
6 100X-DN-04 Tapa de válvulas 1 QT450-10
7 100X-DN-05 90°elbow 1 HPb57-3
8 100X-DN-06 Tapón de tubo de cobre 2 HPb57-3
9 100X-DN-07 Copper   tubeØ10x1 1 TP2M
10 100X-DN-08 Needle   valveDN15 1 HPb57-3
11 100X-DN-09 Float valveDN15 1 HPb57-3
12 100X-DN-10 Ball valveDN15 1 HPb57-3

 

DIMENSIONES
DN L(mm) DN L(mm)
40 211 125 311
50 211 150 355
65 236 200 426
80 255 250 485
100 289 300 530

 

technical   parameters
Presión nominal PN16
Strength   test pressure(MPa) 2.4
Sealing   test pressure(MPa) 1.76
Medios aplicables Agua
Temperatura aplicable 0-80℃

ESPECIFICACIONES

1.Floating valve is a valve that can automatically open and close by sensing the liquid level change through a float and combining it with a remote control signal.
2.It is mainly used for liquid level control of water storage facilities such as water tanks and pools, and has both mechanical feedback and remote operation functions.
3.Liquid level rises: The float rises with the water level, triggers the closing signal through the lever, the valve gradually closes, and the water intake stops.
4.Liquid level drops: The float falls, the lever triggers the opening signal, the valve opens, and water replenishment begins.

FEATURE :

1.Dual control mode:Supports mechanical float automatic control and remote electronic control to meet complex working conditions.
2.Precise liquid level adjustment:High and low liquid level thresholds can be set to achieve precise start and stop, avoiding overflow or idling.
3.High sealing:The valve seat adopts soft seal (such as EPDM rubber), which is leak-free and wear-resistant when closed.
4.Strong anti-interference:The float mechanism and actuator are separated to reduce the impact of water impurities on control accuracy.
5.Low maintenance cost:Modular structure, the actuator or float assembly can be replaced separately in case of failure.

Typical application scenarios

1.Water supply system:Automatic water replenishment and liquid level protection for roof water tanks and underground water tanks.
2.Fire protection system:Water level control of fire water tanks to ensure emergency water reserves.
3.Industrial circulating water:Flow regulation and energy-saving management of cooling towers and boiler water replenishment systems.
4.Agricultural irrigation:Intelligent water level control of large water storage tanks to reduce manual intervention.

PRESIÓN DE TRABAJO

Presión máxima de trabajo 16 bar (230 psi).

ESTÁNDAR

Las pruebas de los productos se realizan de acuerdo con la norma GB/T13927 Prueba de presión de válvulas industriales.

RANGO DE TEMPERATURA

0 °C a 80°C.

REVESTIMIENTO

Revestimiento epoxi unido por fusión.